Article
| Basic features |
Fluke 87V |
Fluke 88V |
Fluke 1507 |
Fluke 1587 |
| Counts | 20000 | 20000 | 6000 | 6000 |
| True RMS readings |
AC | AC | ||
| Basic DC accuracy |
0.05% | 0.1% | 0.09% | |
| Wide bandwidth |
20 kHz |
|||
| Auto/manual ranging |
•/• | •/• | •/• | |
| Measurements | Fluke 87V |
Fluke 88V |
Fluke 1507 |
Fluke 1587 |
| Voltage AC/DC |
1000 V |
1000 V |
1000 V |
|
| Current AC/DC |
10 A |
10 A |
400 mA |
|
| Resistance | 50 MΩ |
50 MΩ |
50 MΩ |
|
| Frequency | 200 kHz |
200 kHz |
100 kHz |
|
| Capacitance | 10 mF |
10 mF |
10 mF |
|
| Temperature | +1090 ºC |
+1090 ºC |
+500 °C |
|
| Conductance | 60 nS |
60 nS |
||
| Duty cycle/pulse width |
•/- | •/• | ||
| Continuity with beeper |
• | • | • | |
| Diode test |
• | • | • | |
| Motor drive measurement |
• | |||
| RPM / Dwell |
•/• | |||
| Microamps | • | |||
| Insulation | Fluke 87V |
Fluke 88V |
Fluke 1507 |
Fluke 1587 |
| Insulation test range |
0.01 MΩ to 10 GΩ |
0.01 MΩ to 2 GΩ |
||
| Pass/Fail function |
• | |||
| Automatic calculation of Polarization Index and Dielectric Absorption Ratio |
• | |||
| Minimum Test Current @ 1kΩ/V: |
1mA | 1mA | ||
| Test Voltages |
50, 100, 250, 500, 1000 V |
50, 100, 250, 500, 1000 V |
||
| Maximum Resistance per Test Voltage: |
50V: 50.0 MΩ 100V: 100.0 MΩ 250V: 200.0 MΩ 500V: 500.0 MΩ 1000V: 10 GΩ |
50V: 50.0 MΩ 100V: 100.0 MΩ 250V: 200.0 MΩ 500V: 500.0 MΩ 1000V: 2 GΩ |
||
| Maximum Resolution per Test Voltage: |
50V: 0.01 MΩ 100V: 0.01 MΩ 250V: 0.1 MΩ 500V: 0.1 MΩ 1000V: 0.1 MΩ |
50V: 0.01 MΩ 100V: 0.01 MΩ 250V: 0.1 MΩ 500V: 0.1 MΩ 1000V: 0.1 MΩ |
||
| Accuracy per Test Voltage: |
50V: ±(3 % + 5)
100V: ±(3 % + 5) 250V: ±(1.5 % + 5) 500V: ±(1.5 % + 5) 1000V: ±(1.5 % + 5) to 2000 MΩ, ±(10 % + 3) above 2000 MΩ |
50V: ±(3 % + 5) 100V: ±(3 % + 5) 250V: ±(1.5 % + 5) 500V: ±(1.5 % + 5) 1000V: ±(1.5 % + 5) to 600 MΩ, ±(10 % + 3) above 600 MΩ |
||
| Test voltage |
50, 100, 250, 500, 1000 V |
50, 100, 250, 500, 1000 V |
||
| Test Voltage Accuracy |
+ 20 %, – 0 % |
+ 20 %, – 0 % |
||
| Short circuit current |
1 mA nominal |
1 mA nominal |
||
| Auto Discharge |
Discharge time < 0.5 second for C = 1 µF or less |
Discharge time < 0.5 second for C = 1 µF or less |
||
| Live circuit indicator |
Inhibit test if terminal voltage > 30 V prior to initialization of test |
Inhibit test if terminal voltage > 30 V prior to initialization of test |
||
| Maximum Capacitive Load |
Operable with up to 1 µF load |
Operable with up to 1 µF load |
||
| Measure Accuracy: |
50 V: ±(3 % + 5) 100 V: ±(3 % + 5) 250 V: ±(1.5 % + 5) 500 V: ±(1.5 % + 5) 1000 V: ±(1.5 % + 5) to 2000 MΩ, ±(10 % + 3) above 2000 MΩ |
50 V: ±(3 % + 5) 100 V: ±(3 % + 5) 250 V: ±(1.5 % + 5) 500 V: ±(1.5 % + 5) 1000 V: ±(1.5 % + 5) to 2000 MΩ, ±(10 % + 3) above 2000 MΩ |
||
| Display | Fluke 87V |
Fluke 88V |
Fluke 1507 |
Fluke 1587 |
| Analog bargraph |
• | • | ||
| Backlight | • | • | • | • |
| Data storage and exchange |
Fluke 87V |
Fluke 88V |
Fluke 1507 |
Fluke 1587 |
| Min-Max recording/with time stamp |
•/- | •/- | •/- | |
| Fast Min-Max |
250 µs |
250 µs |
||
| Display Hold/Auto (Touch) Hold |
•/• | •/• | ||
| Relative | • | • | ||
| Other features |
Fluke 87V |
Fluke 88V |
Fluke 1507 |
Fluke 1587 |
| Smoothing | • | |||
| Removable holster |
• | • | • | • |
| Closed case calibration |
• | • | • | • |
| Separate battery/fuse access |
•/- | •/- | ||
| Automatic power off |
• | • | • | • |
| Low battery indication |
• | • | • | • |
| Warranty and safety |
Fluke 87V |
Fluke 88V |
Fluke 1507 |
Fluke 1587 |
| Lifetime warranty |
• | • | ||
| Warranty (years) |
1 | 3 | ||
| Dangerous voltage indication |
• | • | • | • |
| Input Alert |
• | • | ||
| EN61010-1 CAT III |
1000 V |
1000 V |
1000 V |
1000 V |
| EN61010-1 CAT IV |
600 V |
600 V |
600 V |
600 V |
Posted under Tools
This post was written by carlos on December 4, 2008
Comments
Leave a comment
More Articles
Next Post: Escape/Mariner Hybrid SUV Overview
Previous Post: Honda Civic Hybrid Maintenance Service Tips
Alternative Energy Car News
Hybrid Tools
Fluke Insulation Resistance Tester
The Fluke 1507 is a compact, rugged, reliable, and easy to use.
Fluke Insulation Multimeter
Fluke 87 Multimeter Series V
True-RMS Multimeter with temperature accuracy and diagnostic functions for maximum industrial productivity
Insulation Tester
Auto-ranging and measures up to 2000 MegaOhm with a resolution of 1 K Ohm.
SureGrip™ Stray Voltage Adapter Test Lead Kit
Eliminates stray voltages!